Feasibility study on cardiac resynchronization in the treatment of heart failure by single left bundle branch pacing

文献详情

资源类型:
Pubmed体系:
机构: [1]The First Affiliated Hospital of Kunming Medical University, Kunming 650100, China. [2]University of South Dakota, Vermillion, SD 57069, USA. [3]Yunnan College of Business Management, Kunming 6500032, China
出处:

摘要:
To examine the feasibility of single left bundle branch pacing for cardiac resynchronization therapy (CRT) by carrying out a frequency adaptive atrioventricular delay (RAAVD) algorithm and automatic optimization of the single left bundle branch pacing atrioventricular interval (AVI) based on the right atrioventricular interval (RAS-RVS). Thirty-six patients with CRT class Ia indications according to the European Society of Cardiology 2016 guidelines and implanted with RAAVD functional three-chamber pacemakers were prospectively enrolled in this study. Patients were divided into a single left bundle branch pacing group (n = 21) and a standard biventricular pacing group (n = 15). The optimization of the two groups was performed under standard cardiac colour Doppler ultrasound, followed by the comparison of the QRS width, cardiac function improvement, and echocardiography indicators. The ratio of AVI to the right atrial-right ventricular interval (RAS-RVS) after single LV pacing optimization was defined as the single left bundle branch pacing coefficient (LUBBPε). In comparison to the BVP, the QRS was significantly narrowed (P = 0.017), accompanied by a significantly increased proportion of patients with NYHA class I and II, as well as the 6MWT. Compared with standard biventricular pacing, LVEDD was significantly shortened (P = 0.045), accompanied by significantly improved LAD, AVVTI, EA distance/RR, IVMD, and TS-SD after the operation. RAS-RVS was 156 ± 33 ms, the optimized AVI was 102 ± 10 ms, and LUBBPε was calculated to be 0.66 ± 0.06. Depending on the LUBBPε, a three-chamber pacemaker with a single left bundle branch pacing system was developed based on RAS-RVS-optimized AVI automatically. A three-chamber pacemaker with single left bundle branch pacing can achieve CRT based on RAS-RVS, reaching the optimal AVI of 66% of RAS-RVS.© 2023. The Author(s).

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2024]版:
最新[2023]版:
大类 | 2 区 综合性期刊
小类 | 2 区 综合性期刊
第一作者:
第一作者机构: [1]The First Affiliated Hospital of Kunming Medical University, Kunming 650100, China.
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:52537 今日访问量:0 总访问量:1562 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 昆明医科大学第一附属医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西昌路295号(650032)