高级检索
当前位置: 首页 > 详情页

Application of Insertable Cardiac Monitor in Establishing a Dog Model of Atrial Fibrillation by High-Frequency Right Atrial Pacing

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Kunming Med Univ, Dept Cardiol, Affiliated Hosp 1, Kunming, Yunnan, Peoples R China [2]Kunming Med Univ, Dept Lab Zool, Kunming, Yunnan, Peoples R China [3]Yunnan Fuwai Cardiovasc Hosp, Dept Cardiol, Kunming, Yunnan, Peoples R China
出处:
ISSN:

关键词: Animal Atrial Fibrillation Insertable Cardiac Monitor Models

摘要:
Background: On the base of traditional modeling with high-frequency atrial pacing, insertable cardiac monitor is innovatively used to track the incidence of atrial fibrillation (AF), to observe the efficiency and safety of establishment in AF model. Material/Methods: Twelve adult beagle dogs were randomly divided into a blank control group and an AF model group. The thin- nest available bipolar solid electrode lead-3830 was implanted in AF group, connected to AF pacemaker to establish a high-frequency atrial pacing model by AOO pacing mode, and the occurrence of AF was tracked in real time by an insertable cardiac monitor Reveal LINQ. The areas of the left and the right atrium were measured by echocardiography. In addition, the morphology of left atrial tissues was observed using light and electron microscopes. Results: The insertable cardiac monitor Reveal LINQ sensitively, conveniently, accurately, efficiently, and dynamically re- corded the AF load in AF group. After the successfully establishment of the AF mode, the area of the left atrium and right atrium were significantly enlarged compared with that before modeling by echocardiography. Furthermore, the area of the left atrium and right atrium in the AF group were larger than that in the control group. The morphological observation of the left atrium tissues in both groups prompted the reconstruction of the atrial structure in dogs in the AF group. Conclusions: The application of insertable cardiac monitor Reveal LINQ improves the efficiency of monitoring the AF load, with high sensitivity, convenience, and accuracy.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
JCR分区:
出版当年[2020]版:
Q3 MEDICINE, RESEARCH & EXPERIMENTAL
最新[2023]版:
Q3 MEDICINE, RESEARCH & EXPERIMENTAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者机构: [1]Kunming Med Univ, Dept Cardiol, Affiliated Hosp 1, Kunming, Yunnan, Peoples R China
通讯作者:
通讯机构: [1]Kunming Med Univ, Dept Cardiol, Affiliated Hosp 1, Kunming, Yunnan, Peoples R China [3]Yunnan Fuwai Cardiovasc Hosp, Dept Cardiol, Kunming, Yunnan, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:52537 今日访问量:0 总访问量:1562 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 昆明医科大学第一附属医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西昌路295号(650032)