Purpose. To evaluate the repeatability and reproducibility of quantitative analysis of the morphological corneal changes after orthokeratology treatment using "Image-Pro Plus 6.0" software (IPP). Methods. Three sets of measurements were obtained: two sets by examiner 1 with 5 days apart and one set by examiner 2 on the same day. Parameters of the eccentric distance, eccentric angle, area, and roundness of the corneal treatment zone were measured using IPP. The intraclass correlation coefficient (ICC) and repetitive coefficient (COR) were used to calculate the repeatability and reproducibility of these three sets of measurements. Results. ICC analysis suggested "excellent" reliability of more than 0.885 for all variables, and COR values were less than 10% for all variables within the same examiner. ICC analysis suggested "excellent" reliability for all variables of more than 0.90, and COR values were less than 10% for all variables between different examiners. All extreme values of the eccentric distance and area of the treatment zone pointed to the same material number in three sets of measurements. Conclusions. IPP could be used to acquire the exact data of the characteristic morphological corneal changes after orthokeratology treatment with good repeatability and reproducibility. This trial is registered with trial registration number: ChiCTR-IPR-14005505.
基金:
National Natural Science Foundation of China, ChinaNational Natural Science Foundation of China [81200716]
语种:
外文
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2017]版:
大类|4 区医学
小类|4 区医学:研究与实验4 区眼科学
最新[2023]版:
大类|4 区医学
小类|4 区眼科学
JCR分区:
出版当年[2016]版:
Q3MEDICINE, RESEARCH & EXPERIMENTALQ3OPHTHALMOLOGY
第一作者机构:[1]Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangzhou 510060, Guangdong, Peoples R China;[2]Tianming Ophthalmol & Optometry Clin, Kunming, Peoples R China;
通讯作者:
通讯机构:[1]Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangzhou 510060, Guangdong, Peoples R China;
推荐引用方式(GB/T 7714):
Mei Ying,Tang Zhiping,Li Zhouyue,et al.Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software[J].JOURNAL OF OPHTHALMOLOGY.2016,2016:doi:10.1155/2016/1732476.
APA:
Mei, Ying,Tang, Zhiping,Li, Zhouyue&Yang, Xiao.(2016).Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software.JOURNAL OF OPHTHALMOLOGY,2016,
MLA:
Mei, Ying,et al."Repeatability and Reproducibility of Quantitative Corneal Shape Analysis after Orthokeratology Treatment Using Image-Pro Plus Software".JOURNAL OF OPHTHALMOLOGY 2016.(2016)