高级检索
当前位置: 首页 > 详情页

Explorating the Involvement of Plasma Sestrin2 in Obstructive Sleep Apnea(Open Access)

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Respiratory and Critical Care Medicine, First Affiliated Hospital of Kunming Medical University, Kunming, China [2]Clinical Medicine, 2015 Grade, Kunming Medical University, Kunming, China [3]Department of Respiratory Medicine, Beijing Friendship Hospital, Capital Medical University, Beijing, China
出处:
ISSN:

摘要:
Obstructive sleep apnea (OSA) can lead to serious complications such as coronary heart disease and hypertension due to oxidative stress. Sestrin2 expression is upregulated under conditions of oxidative stress. This study aimed to explore whether Sestrin2 was involved in OSA. OSA and healthy control subjects were recruited and matched with age, gender, and body mass index (BMI). Plasma Sestrin2 levels were measured and compared. A multivariate stepwise regression model was used to detect the relationship between Sestrin2 and other variable factors. The Sestrin2 levels were compared between before and after four weeks treatment by nasal continuous positive airway pressure (nCPAP) in severe OSA patients. Fifty-seven subjects were divided into two groups: control group (39.33 ± 9.40 years, n = 21) and OSA group (38.81 ± 7.84 years, n = 36). Plasma Sestrin2 levels increased in the OSA group (control group 2.06 ± 1.76 ng/mL, OSA group 4.16 ± 2.37 ng/mL; P=0.001). Sestrin2 levels decreased after four-week nCPAP treatment (pre-nCPAP 5.21 ± 2.32 ng/mL, post-nCPAP 4.01 ± 1.54 ng/mL; P=0.004). Sestrin2 was positively correlated with apnea/hypopnea index (AHI) oxygen desaturation index, while negatively correlated with mean oxygen saturation. Moreover, these correlations remained unchanged after adjusting for gender, age, waist-to-hip ratio, and body mass index. Multiple regression analysis showed that there was an association between Sestrin2 and AHI. Our findings suggest that Sestrin2 is involved in OSA. The increase of plasma Sestrin2 is directly related to the severity of OSA. To some extent, Sestrin2 may be useful for determining the severity of OSA and monitoring the effect of CPAP. In addition, since some complications of OSA such as coronary heart disease and diabetes are usually related with oxidative stress, the role of Sestrin2 in those OSA complications needs further study. © 2019 Rong Jiang et al.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 4 区 医学
小类 | 4 区 呼吸系统
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 呼吸系统
JCR分区:
出版当年[2019]版:
Q4 RESPIRATORY SYSTEM
最新[2023]版:
Q3 RESPIRATORY SYSTEM

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者机构: [1]Department of Respiratory and Critical Care Medicine, First Affiliated Hospital of Kunming Medical University, Kunming, China [2]Clinical Medicine, 2015 Grade, Kunming Medical University, Kunming, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:52537 今日访问量:0 总访问量:1562 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 昆明医科大学第一附属医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西昌路295号(650032)