Background: This study set out to evaluate the utility of cerebrovascular virtual non-contrast (VNC) scans. Materials and Methods: Conventional non-contrast (CNC) and dual-energy computed tomography angiography (DE-CTA) head scans were conducted on 100 subjects, of which 46 were normal, 15 had parenchymal hematomas of the brain, 13 had ischemic infarction, 22 had tumors, and 4 had calcified lesions. VNC images were extracted from the DE-CTA head scans by post-processing. The true (or convenional) and VNC images were compared in terms of the mean CT attenuation value and signal-to-noise ratio (SNR) of the cerebral parenchyma, the image quality, the lesion detection sensitivity, and the radiation exposure level. Results: The image qualities of the CNC and VNC scans were (4.95 ± 0.22) points and (3.94 ± 0.24) points (t = 31.18, P < 0.05), the mean CT values for the CNC and VNC images were (34.6 ± 2.44) and (28.6 ± 5.40) HU (t = 10.126, P < 0.05), the SNRs were (9.45 ± 1.26) and (6.87 ± 1.77), and the HU for white matter was (t = 11.859, P<0.05), respectively. The effective radiation doses from the DE-CTA head scans and the convenional non-contrast scans were (8.55 ± 0.57) mSv and (9.41 ± 1.00) mSv, respectively. No significant difference in the lesion detection sensitivities was observed between the CNC and VNC scans, except for tiny calcified lesions, which could not be identified by a VNC scan. Conclusion: VNC and contrast-enhanced images could be obtained from DE-CTA head scans and could aid in the diagnosis of cerebral lesions. The radiaion dose from the VNC scan was less than that from the CNC scan.
语种:
外文
中科院(CAS)分区:
出版当年[2017]版:
大类|4 区医学
小类|4 区核医学
最新[2023]版:
大类|4 区医学
小类|4 区核医学
第一作者:
第一作者机构:[1]Medical Imaging Center, The First Hospital Afiliated Kunming Medical College, Kunming, 650032, China
通讯作者:
推荐引用方式(GB/T 7714):
Han D,Xie X.J,Wen L.Clinical applications of virtual, non-contrast head images derived from dual-source, dual-energy cerebrovascular computed tomography angiography(Open Access)[J].International Journal of Radiation Research.2016,14(2):doi:10.18869/acadpub.ijrr.14.2.159.
APA:
Han, D,Xie, X.J&Wen, L.(2016).Clinical applications of virtual, non-contrast head images derived from dual-source, dual-energy cerebrovascular computed tomography angiography(Open Access).International Journal of Radiation Research,14,(2)
MLA:
Han, D,et al."Clinical applications of virtual, non-contrast head images derived from dual-source, dual-energy cerebrovascular computed tomography angiography(Open Access)".International Journal of Radiation Research 14..2(2016)