高级检索
当前位置: 首页 > 详情页

Evaluation of Multimodal Biometric Parameters for Diagnosing Acute Angle Closure Secondary to Lens Subluxation

| 导出 | |

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Ophthalmology, The First Affiliated Hospital with Nanjing Medical University, Nanjing, 210029, Jiangsu, China. [2]Department of Ophthalmology, The First Affiliated Hospital of Kunming Medical University, Kunming, 650032, Yunnan, China.
出处:
ISSN:

关键词: Biometric parameters Acute secondary angle closure due to lens subluxation Acute primary angle closure Anterior chamber depth UBM IOL Master

摘要:
To evaluate the clinical characteristics and multimodal biometric parameters from ultrasound biomicroscopy (UBM) and IOL Master biometry of patients with acute secondary angle-closure due to lens subluxation (ASAC-LS), acute primary angle-closure (APAC), and cataract.This retrospective study included 22 eyes with ASAC-LS, 27 eyes with APAC, and 39 eyes with cataract. Gender, age, affected eye, best corrected visual acuity, axial length, central corneal thickness, and anterior chamber depth (ACD) assessed by UBM and IOL Master were measured and compared between the three groups. In addition, we compared the ratio of ACD (ACD ratio) and the difference of ACD (ACD difference) measured by the two instruments. Logistic regression analysis was conducted to evaluate the predictive factors for lens subluxation. Receiver operating characteristic (ROC) curves were plotted to obtain a suitable cutoff value of biometric parameters to separate ASAC-LS cases from APAC and cataract cases.In the ASAC-LS group, the median (interquartile range [IQR]) ACD measured by IOL Master was 2.47 (IQR 1.85-2.92) mm while the median ACD measured by UBM was 3.11 (IQR 2.60-3.76) mm. The difference of ACD measured by the two instruments was statistically significant in the ASAC-LS group (P < 0.001) whereas the differences were not statistically significant in the APAC group (P = 0.521) and cataract group (P = 0.204). Subsequent pairwise comparison revealed that only the ACD difference (0.40 [IQR 0.22-1.08] mm) and ACD ratio (1.18 [IQR 1.07-1.40]) in the ASAC-LS group were significantly different from those in the APAC group (ACD difference 0.02 [IQR 0.01-0.07] mm; ACD ratio 1.01 [IQR 1.00-1.04]) and cataract group (ACD difference 0.09 [IQR 0.01-0.14] mm; ACD ratio 1.03 [IQR 1.00-1.04]) (all P < 0.001). The ACD difference and ACD ratio were significantly associated with lens subluxation in the multivariate logistic regression analysis (P < 0.001 and P = 0.001, respectively). Additionally, the ROC curve analysis showed that the ACD difference at 0.235 mm and the ACD ratio at 1.080 were the respective cut-off values for lens subluxation, with a sensitivity of 77.3% and specificity of 100.0%.Our findings provide a new option for identifying lens subluxation. Specifically, combining the ACD from UBM and IOL Master may be helpful for differential diagnosis of ASAC-LS.© 2022. The Author(s).

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2024]版:
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 眼科学
JCR分区:
出版当年[2023]版:
Q2 OPHTHALMOLOGY
最新[2023]版:
Q2 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2023版] 出版当年五年平均 出版前一年[2022版]

第一作者:
第一作者机构: [1]Department of Ophthalmology, The First Affiliated Hospital with Nanjing Medical University, Nanjing, 210029, Jiangsu, China.
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:52537 今日访问量:0 总访问量:1562 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 昆明医科大学第一附属医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西昌路295号(650032)