高级检索
当前位置: 首页 > 详情页

A Systematic Review and Meta-analysis on Ultrasound Detection of Thyroid Cancer in China

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Kunming Med Univ, Dept Ultrasound, Affiliated Hosp 1, 295 Xichang Rd, Kunming 650032, Yunnan, Peoples R China
出处:
ISSN:

关键词: ACR-TIRADS China C-TIRADS FNA (Fine Needle Aspiration) Malignant Ultrasound Thyroid nodules

摘要:
Background: One major drawback of using ultrasound for diagnosing thyroid nodules is its limited ability to distinguish between benign and malignant nodules. In China, the common methods for risk stratification and guiding fine needle aspiration (FNA) in diagnosing thyroid nodules are the Chinese Thyroid Imaging Reports and Data Systems (C-TIRADS) and American College of Radiology-Thyroid Imaging Reporting and Data System (ACR-TIRADS). Objectives: This review seeks to assess the effectiveness of C-TIRADS and ACR-TIRADS in accurately identifying the risk of malignancy in Chinese patients suspected of thyroid cancer. Methods: A detailed search was conducted in PubMed, Google Scholar, Medline, Embase, Web of Science, Cochrane, and China National Knowledge Infrastructure (CNKI) databases from January 2018 to December 2022. The analysis only considered original articles from China reporting the use of C-TIRADS and ACR-TIRADS confirmed by histology and FNA. Results: This review analyzed 26 studies with a total of 23,064 thyroid nodules from 19,114 patients to compare the diagnostic performance of C-TIRADS and ACR-TIRADS in predicting malignancy risk in thyroid nodules. Although the malignancy rates in each risk category were similar between the two systems, the TIRADS showed better diagnostic performance than C-TIRADS in terms of pooled specificity (95.0 % vs. 66.8 % of C-TIRADS). However, the pooled analysis showed that C-TIRADS had a better pooled sensitivity (94.6 % vs. 76.5% of ACR-TIRADS). The diagnostic odds ratio was 1.37 (95 % CI: 0.75-2.51) for ACR-TIRADS and 0.89 (95 % CI: 0.36-2.16) for C-TIRADS. Conclusion: Based on the results, both C-TIRADS and ACR-TIRADS are effective in predicting the risk of malignancy in thyroid nodules with similar overall diagnostic accuracy. The combination of both systems can be beneficial in enhancing accuracy in suspicious or uncertain cases. The long-term experience of the trained radiologists can readily help in concluding the diagnosis. As no single system or combination of systems can provide a 100% accurate prediction of the malignancy of thyroid nodules, the ultimate diagnosis relies on the concluding assessment of experienced radiologists and the medical team.

语种:
WOS:
中科院(CAS)分区:
出版当年[2024]版:
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
JCR分区:
出版当年[2023]版:
Q3 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q3 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2023版] 出版当年五年平均 出版前一年[2022版]

第一作者:
第一作者机构: [1]Kunming Med Univ, Dept Ultrasound, Affiliated Hosp 1, 295 Xichang Rd, Kunming 650032, Yunnan, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:56916 今日访问量:2 总访问量:1772 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 昆明医科大学第一附属医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西昌路295号(650032)