The Clinical Efficacy Evaluation of the KHA-200 Hemoperfusion Device in the Treatment of End-Stage Renal Disease Patients Undergoing Blood Purification Therapy

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Nephrology, The First Affiliated Hospital of Kunming Medical University, Kunming, China. [2]Department of Otolaryngology, The First Affiliated Hospital of Kunming Medical University, Kunming, China. [3]Department of Medical record, The Third People's Hospital of Kunming, Kunming, China.
出处:
ISSN:

关键词: Hemoperfusion Hemodialysis End-stage renal disease Effect evaluation

摘要:
The aim of the study was to assess the impact of employing the KHA-200 hemoperfusion device in conjunction with hemodialysis therapy in the elimination of serum solutes among maintenance hemodialysis (MHD) patients.A total of ninety-two MHD patients from our hospital's hemodialysis center were judiciously chosen and allocated randomly into two groups: the conventional hemodialysis group, serving as the control group, and the group utilizing the KHA-200 hemoperfusion device in combination with hemodialysis, denoted as the experimental group, in a 1:1 ratio. We compared variations in serum solute indices, including blood urea nitrogen, creatinine, potassium, calcium, phosphorus, high-sensitivity C-reactive protein (hsCRP), interleukin-6 (IL-6), β2-microglobulin (β2-MG), parathyroid hormone (PTH), homocysteine (Hcy), albumin, both prior to and post-treatment. Meanwhile, a comparison of the serum solute clearance rates in the two groups was performed.Following treatment, both groups exhibited substantial reductions in blood urea nitrogen, creatinine, uric acid, potassium, phosphorus, PTH, and Hcy (p < 0.001). There were no statistically significant distinctions between the two groups in terms of urea nitrogen, creatinine, uric acid, and potassium clearance (p > 0.05). Conversely, the experimental group demonstrated a significant effect on the elimination of IL-6 and β2-MG (p < 0.001). Furthermore, the experimental group's performance in reducing blood phosphorus, PTH, IL-6, β2-MG, and Hcy was significantly superior to that of the control group (p < 0.05). Moreover, the reduction in systolic blood pressure in the experimental group was better than in the control group.Employing the KHA-200 hemoperfusion device in tandem with hemodialysis excels in removing blood phosphorus and certain medium-sized uremic toxins, including PTH, IL-6, β2-MG, and Hcy, surpassing the performance of conventional hemodialysis.© 2025 The Author(s). Published by S. Karger AG, Basel.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2026]版:
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 泌尿学与肾脏学
JCR分区:
出版当年[2025]版:
最新[2024]版:
Q1 UROLOGY & NEPHROLOGY

影响因子: 最新[2024版] 最新五年平均 出版当年[2025版] 出版当年五年平均 出版前一年[2024版]

第一作者:
第一作者机构: [1]Department of Nephrology, The First Affiliated Hospital of Kunming Medical University, Kunming, China.
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:70786 今日访问量:0 总访问量:2273 更新日期:2025-12-01 建议使用谷歌、火狐浏览器 常见问题

技术支持:重庆聚合科技有限公司