Image quality evaluation for CARE kV technique combined with iterative reconstruction for chest computed tomography scanning

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Medical Imaging Department, the First Affiliated Hospital, Dali University, Dali,Kunming,China. [2]Department of Cardiology, Shanghai General Hospital,Kunming,China. [3]Medical ImagingDepartment, the First Affiliated Hospital, Kunming Medical University, Kunming,China.
出处:
ISSN:

关键词: CARE kV chest iterative reconstruction radiation dosage tomograph x-ray computed

摘要:
Background: To investigate the radiation dose and image quality for iterative reconstruction combined with the CARE kV technique in chest computed tomography (CT) scanning for physical examination. Methods: A total of 130 patients who underwent chest CT scanning were randomly chosen and the quality reference value was set as 80 mAs. The scanning scheme was set and the patients were randomly divided into groups according to the scanning scheme. Sixty patients underwent a chest scan with 100kV using the CARE kV technique and SAFIRE reconstruction (value= 3) (experimental group) and the other 70 patients underwent chest scanning with 120kV (control group). The mean CT value, image noise (SD), and signal-to-noise ratio (SNR) of the apex of the lung, the level of the descending aorta bifurcation of the trachea, and the middle area of the left atrium were measured. The image quality was assessed on a 5-point scale by two radiologists and results of the two groups were compared. The CT dose index of the volume (CTDIvol), dose length product (DLP), and effective dose (ED) were compared. Results: All the images for both groups satisfied the diagnosis requirement. There was no statistical difference in the image quality between the two methods (P > 0.05). The mean CT value of the apex of the lung, the level of the descending aorta bifurcation of the trachea, and the middle area of the left atrium were not significantly different for both groups (P > 0.05), while the image noise (SD) and the signal-to-noise ratio (SNR) of the apex of the lung, the level of the descending aorta bifurcation of the trachea, and the middle area of the left atrium were statistically different for both groups (P < 0.05). The CTDIvol was 3.29 +/- 1.17 mGy for the experimental group and 5.30 +/- 1.53 mGy for the control group. The DLP was 114.9 +/- 43.73mGy cm for the low-dose group and 167.6 +/- 44.59mGy cm for the control group. The ED was 1.61 +/- 0.61 mSv for the low-dose group and 2.35 +/- 0.62 mSv for the control group (P < 0.05). Conclusion: The CARE kV technique combined with iterative reconstruction for chest CT scanning for physical examination could reduce the radiation dosage and improve CT image quality, which has a potential clinical value for imaging the thorax.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 4 区 医学
小类 | 3 区 医学:内科
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
JCR分区:
出版当年[2017]版:
Q2 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q2 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2017版] 出版当年五年平均 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者机构: [1]Medical Imaging Department, the First Affiliated Hospital, Dali University, Dali,Kunming,China.
共同第一作者:
通讯作者:
通讯机构: [*1]Medical Imaging Department, the First Affiliated Hospital, Kunming Medical University, Kunming
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:52537 今日访问量:0 总访问量:1562 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 昆明医科大学第一附属医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西昌路295号(650032)