高级检索
当前位置: 首页 > 详情页

Diagnostic value of gelatin particles aggregation less-sensitive method for HIV-1 antibody in human gingival crevicular fluid

| 认领 | 导出 |

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Kunming Med Univ, Sch Stomatol, Dept Oral Med, Kunming 650500, Yunnan, Peoples R China; [2]Kunming Med Univ, Sch Stomatol, Dept Prosthet Dent, 1168 West Chunrong Rd,Yuhua St, Kunming 650500, Yunnan, Peoples R China; [3]Kunming Med Univ, Affiliated Hosp 1, Dept Infect Dis, Kunming 650032, Yunnan, Peoples R China; [4]Kunming Med Univ, Stomatol Hosp, Dept Periodont, Kunming 650031, Yunnan, Peoples R China
出处:
ISSN:

关键词: Antibody detection ELISA gelatin particles aggregation less-sensitive method gingival crevicular fluid human immunodeficiency virus type-1 sensitivity

摘要:
This study detected the HIV-1 antibody in gingival crevicular fluid (GCF) using gelatin particles aggregation less-sensitive (PA-LS) method, which aimed to provide a foundation for non-invasive HIV infection test in dental clinic. GCF samples and serum samples were collected from three groups, including HIV-1 positive group, drug users group and general population group. Simultaneously the HIV-1 antibodies in GCF samples were detected by PA-LS, and the HIV-1 antibodies in serum samples were screened by ELISA and confirmed by western blot. According to the final results of western blot, it was evaluated about the sensitivity, specificity, omission diagnostic rate, mistake diagnostic rate, positive predictive value and negative predictive value of PA-LS method. For HIV-1 positive group, the sensitivity of PA-LS used to detect HIV-1 antibody in GCF samples was 100%, the omission diagnostic rate was 0. For drug users group, when used to detect the HIV-1 antibody, the sensitivity, specificity, omission diagnostic rate, mistake diagnostic rate, positive predictive value and negative predictive value of PA-LS were 100%, 99.10%, 0%, 0.90%, 95.57%, and 100%, respectively; the results of ELISA/WB and PA-LS had a high consistency (Kappa >0.8, P<0.01) and no significant difference (P>0.05). For general population, all GCF samples showed HIV-1 antibody negative results. In this study, PA-LS used to test HIV-1 antibody in GCF samples showed a good effect, and was non-invasive, simple, cost-effective compared to ELISA used to detect HIV-1 antibody in serum samples.

基金:
语种:
WOS:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
最新[2023]版:
JCR分区:
出版当年[2017]版:
Q4 MEDICINE, RESEARCH & EXPERIMENTAL
最新[2023]版:
Q4 MEDICINE, RESEARCH & EXPERIMENTAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2017版] 出版当年五年平均 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者机构: [1]Kunming Med Univ, Sch Stomatol, Dept Oral Med, Kunming 650500, Yunnan, Peoples R China;
通讯作者:
通讯机构: [2]Kunming Med Univ, Sch Stomatol, Dept Prosthet Dent, 1168 West Chunrong Rd,Yuhua St, Kunming 650500, Yunnan, Peoples R China;
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:53661 今日访问量:0 总访问量:1665 更新日期:2024-11-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 昆明医科大学第一附属医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西昌路295号(650032)