高级检索
当前位置: 首页 > 详情页

Diagnostic value of gelatin particles aggregation less-sensitive method for HIV-1 antibody in human gingival crevicular fluid

| 认领 | 导出 |

文献详情

资源类型:
机构: [1]Department of Oral Medicine, Kunming Medical University School of Stomatology,Kunming 650500, Yunnan Province, China [2]Department of Infectious Diseases, The First Affiliated Hospital ofKunming Medical University, Kunming 650032, Yunnan Province, China [3]Department of Periodontics, Affiliated toStomatology Hospital of Kunming Medical University, Kunming 650031, Yunnan Province, China [4]Department of Prosthetic Dentistry, Kunming Medical University School of Stomatology,Kunming 650500, Yunnan Province, China
出处:
ISSN:

关键词: Antibody detection ELISA Gelatin particles aggregation less-sensitive method Gingival crevicular fluid Human immunodeficiency virus type-1 Sensitivity

摘要:
This study detected the HIV-1 antibody in gingival crevicular fluid (GCF) using gelatin particles aggregation less-sensitive (PA-LS) method, which aimed to provide a foundation for non-invasive HIV infection test in dental clinic. GCF samples and serum samples were collected from three groups, including HIV-1 positive group, drug users group and general population group. Simultaneously the HIV-1 antibodies in GCF samples were detected by PA-LS, and the HIV-1 antibodies in serum samples were screened by ELISA and confirmed by western blot. According to the final results of western blot, it was evaluated about the sensitivity, specificity, omission diagnostic rate, mistake diagnostic rate, positive predictive value and negative predictive value of PA-LS method. For HIV-1 positive group, the sensitivity of PA-LS used to detect HIV-1 antibody in GCF samples was 100%, the omission diagnostic rate was 0. For drug users group, when used to detect the HIV-1 antibody, the sensitivity, specificity, omission diagnostic rate, mistake diagnostic rate, positive predictive value and negative predictive value of PA-LS were 100%, 99.10%, 0%, 0.90%, 95.57%, and 100%, respectively; the results of ELISA/WB and PA-LS had a high consistency (Kappa >0.8, P<0.01) and no significant difference (P>0.05). For general population, all GCF samples showed HIV-1 antibody negative results. In this study, PA-LS used to test HIV-1 antibody in GCF samples showed a good effect, and was non-invasive, simple, cost-effective compared to ELISA used to detect HIV-1 antibody in serum samples. © 2017, E-Century Publishing Corporation. All rights reserved.

基金:
语种:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
最新[2023]版:
第一作者:
第一作者机构: [1]Department of Oral Medicine, Kunming Medical University School of Stomatology,Kunming 650500, Yunnan Province, China
共同第一作者:
通讯作者:
通讯机构: [4]Department of Prosthetic Dentistry, Kunming Medical University School of Stomatology,Kunming 650500, Yunnan Province, China [*1]Department of Prosthetic Dentistry, Kunming Medical University School of Stomatology, No.1168 West of Chunrong Road, Yuhua Street, Chenggong New City, Kunming 650500, Yunnan Province, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:52537 今日访问量:0 总访问量:1562 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 昆明医科大学第一附属医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西昌路295号(650032)