Application of 270 mgl/mL Iodinated Contrast Media in Dual-Source Computed Tomography Coronary Artery Imaging

| 导出 | |

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Department ofMedical Imaging, The First Affiliated Hospital, Kunming Medical University, Kunming 650032, China.
出处:
ISSN:

关键词: Contrast agent Contrast to noise ratio Coronary angiography Signal noise ratio

摘要:
Background: This study aimed to explore the application of 270 mg l/mL iodinated contrast agent with a tube voltage of 100 kV scanning in coronary computed tomography angiography (CCTA). Methods: This CCTA study was a prospective observational study. The two radiologists were blinded to both patient information and image date arrangement. One-hundred twenty patients (body mass index < 25.0 kg/m(2)) were randomly divided into three groups based on contrast agent concentrations of 370, 320, and 270 mg l/mL, scanning at an injection rate of 5 ml/s. Then, the coronary artery branches of the three groups were compared, and the display rate, mean computed tomography (CT) value, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), image noise, and radiation dose were analyzed. Results: The artery display rates of the four main branches of coronaries in the three groups were all 100%, and the difference in the display rates of the remaining small branches in the three groups exhibited no statistical significance (p > 0.05). A comparison of the mean CT value of the coronary artery of three groups in the ascending aorta, descending aorta, left main, left ventricular wall, right coronary artery, left anterior descending, and left circumflex showed a statistically significant difference (p < 0.05). A comparison of the SNR, CNR, image noise, and radiation dose showed no statistically significant difference (p > 0.05). Conclusions: Using a tube voltage of 100 kV combined with 270 mg l/mL iodinated contrast media in CCTA examination can achieve the "double low dose" effect while ensuring image quality.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2015]版:
大类 | 4 区 医学
小类 | 4 区 心脏和心血管系统
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 心脏和心血管系统
JCR分区:
出版当年[2014]版:
Q4 CARDIAC & CARDIOVASCULAR SYSTEMS
最新[2023]版:
Q3 CARDIAC & CARDIOVASCULAR SYSTEMS

影响因子: 最新[2023版] 最新五年平均 出版当年[2014版] 出版当年五年平均 出版前一年[2013版] 出版后一年[2015版]

第一作者:
第一作者机构: [1]Department ofMedical Imaging, The First Affiliated Hospital, Kunming Medical University, Kunming 650032, China.
通讯作者:
通讯机构: [*1]Department ofMedical Imaging, The First Affiliated Hospital, Kunming Medical University, Kunming 650032, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:57189 今日访问量:0 总访问量:1788 更新日期:2025-01-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 昆明医科大学第一附属医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西昌路295号(650032)