Chinese Journal Of Medical Imaging Technology.2014,30(12):
ISSN:
1003-3289
关键词:
Angiography
Pulmonary embolism
Radiography
dual-energy scanned projection
Tomography
X-ray computed
摘要:
Objective: To evaluate the clinical value of Lung Vessels software in diagnosis of pulmonary embolism (PE) in dual energy CT pulmonary angiography (DE-CTPA). Methods: Totally 49 patients of suspected PE underwent DE-CTPA. Lung Vessels software was used to process the images and the location and number of the abnormal vessel were recorded. The sensitivity, specificity, positive predictive value and negative predictive value of Lung Vessels were calculated with CTPA combined with clinic as gold standard based on patient, segment and sub-segment numbers. Results: CTPA revealed 29 patients of PE with 188 diseased vessels, including 138 segments and 50 subsegments. The sensitivity, specificity, positive predictive value and negative predictive value of Lung Vessels in diagnosing PE was 96.55% (28/29), 45.00% (9/20), 71.79% (28/39), 90.00% (9/10) for patient as a unit, 65.94% (91/138), 80.38% (598/744), 38.40% (91/237), 92.71% (598/645) for segment as a unit and 64.00% (32/50), 92.24% (1581/1714), 19.39% (32/165), 98.87% (1581/1599) for subsegment as a unit, respectively. Conclusion: In DE-CTPA, Lung Vessels software can directly show the lung vessels, which is helpful for diagnosing PE, especially segmental and subsegmental PE with potential application prospects. Copyright © 2014 by the Press of Chinese Journal of Medical Imaging and Technology.
第一作者:
Xie, X.-J
第一作者机构:
[1]Department of Medical Imaging, the First Affiliated Hospital of Kunming Medical University, Kunming, 650032, China
通讯作者:
Xie, X.-J;Han, D
推荐引用方式(GB/T 7714):
Xie X.-J,Deng Y.-M,Han D,等.Lung Vessels software in diagnosis of pulmonary embolism in dual energy CT pulmonary angiography[J].Chinese Journal Of Medical Imaging Technology.2014,30(12):