Assessment of bone densitometry using radiography with a step-wedge phantom: a pilot study of the forearm

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Radiology, Beijing Jishuitan Hospital, Beijing, China [2]Department of Radiology, The First People’s Hospital of Yunnan Province, Kunming, China [3]Department of Orthopedics, Beijing Jishuitan Hospital, Beijing, China [4]School of Biomedical Engineering & Imaging Sciences, King’s College London, St Thomas’ Hospital, London, UK [5]Department of Radiology, The First Affiliated Hospital of Kunming Medical University, Kunming, China [6]Department of Traumatic Orthopedics, Beijing Jishuitan Hospital, Beijing, China [7]Department of Medicine 3, FAU University Erlangen-Nürnberg and Universitätsklinikum Erlangen, Erlangen, Germany [8]Institute of Medical Physics, University of Erlangen, Erlangen, Germany
出处:
ISSN:

关键词: Radiographic absorptiometry (RA) dual-energy X-ray absorptiometry (DXA) bone mineral density (BMD) forearm

摘要:
Background: Radiographic absorptiometry (RA) is one of the earliest methods of bone densitometry and has been used to measure the phalanges and metacarpals where soft tissue attenuation is minimal. The aim of this study was to determine whether the technique can be adapted to correct for soft tissue attenuation and measure areal bone mineral density (aBMD) in the forearm. Methods: A total of 51 patients referred for a clinical spine and hip dual-energy X-ray absorptiometry (DXA) examination and 8 young and middle-aged volunteers were recruited to this study. The first 29 participants (20 women, 9 men, aged 61 +/- 14 years) served as the training cohort, and the remaining 30 (20 women, 10 men, aged 55 +/- 16 years) comprised the validation cohort. All participants underwent a DXA scan of their non-dominant forearm, and a digital X-ray image of the same arm was acquired with a step phantom. Identical regions of interest (ROIs) in the radius and ulna at the one-third radius site were measured on the X-ray and DXA images, and a soft tissue ROI was measured on X-ray images between the radius and ulna. The X-ray measurements in the training cohort were expressed as equivalent step phantom thickness (Eq. SPT) and used to estimate forearm aBMD using a linear equation calibrated against the DXA scans. Estimates of forearm aBMD made from the digital X-ray images acquired in the validation cohort were compared with the results of the DXA scans. Results: Digital X-ray estimates of radius and ulna aBMD at the one-third radius site in the validation cohort showed a good correlation with GE-Lunar iDXA scanner measurements (r=0.795; P<0.001). The Bland-Altman plot had a mean bias of -0.002 g/cm(2) and 95% limits of agreement of -0.185 to +0.181 g/cm(2). Conclusions: Digital X-ray estimates of proximal forearm aBMD corrected for soft tissue attenuation correlated with DXA measurements with correlation coefficients comparable to those seen for other peripheral bone densitometry technologies.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 2 区 医学
小类 | 3 区 核医学
最新[2023]版:
大类 | 2 区 医学
小类 | 3 区 核医学
JCR分区:
出版当年[2022]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]Department of Radiology, Beijing Jishuitan Hospital, Beijing, China [2]Department of Radiology, The First People’s Hospital of Yunnan Province, Kunming, China
共同第一作者:
通讯作者:
通讯机构: [1]Department of Radiology, Beijing Jishuitan Hospital, Beijing, China [6]Department of Traumatic Orthopedics, Beijing Jishuitan Hospital, Beijing, China [*1]Department of Radiology, Beijing Jishuitan Hospital, 31 Xinjiekou East Street, Beijing 100035, China. [*2]Department of Traumatic Orthopedics, Beijing Jishuitan Hospital, 31 Xinjiekou East Street, Beijing 100035, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:53656 今日访问量:0 总访问量:1665 更新日期:2024-11-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 昆明医科大学第一附属医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西昌路295号(650032)