高级检索
当前位置: 首页 > 详情页

A Comparison Between X-ray Imaging and an Innovative Computer-aided Design Method Based on Weightbearing CT Scan images for Assessing Hallux Valgus

| 导出 | |

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [a]Department of Orthopedics, the First Affiliated Hospital of Kunming Medical University, Kunming, 650000, China [b]Xiangyang Central Hospital, Affiliated Hospital Of Hubei University of Arts and Science.
出处:
ISSN:

关键词: 4 computer-aided design DMAA hallux valgus HVA IMA MIMICS x-ray imaging

摘要:
With the development of recent technology, radiographs can be saved digitally, and angular measurements can be processed using various software packages. We developed an innovative computer-aided design method with Materialize Interactive Medical Image Control System software to measure hallux valgus angle (HVA), the intermetatarsal angle (IMA), and the distal metatarsal articular angle (DMAA) and assessed its concordance with traditional X-ray imaging methods. All measurements were carried out on 42 feet from 26 adult patients diagnosed with hallux valgus who were prospectively selected from July 2016 to April 2018. Standing X-ray radiograph and weightbearing computed tomography scans were conducted on all patients, and HVA, IMA, and DMAA were generated using both a traditional X-ray method and our innovative method. Two different observers assessed measurements for each patient. Finally, statistical analyses were conducted to assess the reliability of the measurements. Both X-ray imaging and our innovative method had strong interobserver and test-retest reliability. The ICC of X-ray imaging was 0.945, p <.001, and the ICC of the innovative method was 0.915, p <.001. There was no statistical difference between the 2 methods for HVA and IMA measurements (p >.05); however, a difference was detected for DMAA (p <.05). Bland-Altman analyses demonstrated a high degree of agreement between the 2 methods for HVA and IMA, but a significant difference for DMAA. From the results, we concluded that our innovative computer-aided design method is a feasible, reliable way to quantitatively assess HVA, IMA, and DMAA, and it is likely more accurate for measuring DMAA. © 2020

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 4 区 医学
小类 | 4 区 骨科 4 区 外科
最新[2023]版:
大类 | 4 区 医学
小类 | 4 区 骨科 4 区 外科
JCR分区:
出版当年[2021]版:
Q4 ORTHOPEDICS Q4 SURGERY
最新[2023]版:
Q3 ORTHOPEDICS Q3 SURGERY

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [a]Department of Orthopedics, the First Affiliated Hospital of Kunming Medical University, Kunming, 650000, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:53611 今日访问量:17 总访问量:1665 更新日期:2024-11-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 昆明医科大学第一附属医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西昌路295号(650032)