高级检索
当前位置: 首页 > 详情页

Hemodynamic effects of different fluid volumes for a fluid challenge in septic shock patients

Hemodynamic effects of different fluid volumes for a fluid challenge in septic shock patients

文献详情

资源类型:
WOS体系:
Pubmed体系:
中文论文体系:

收录情况: ◇ 统计源期刊 ◇ CSCD-C ◇ 卓越:领军期刊 ◇ 中华系列

作者:
机构: [1]北京协和医院
出处:

关键词: Cardiac output (CO) Fluid challenge (FC) Arterial load Effective arterial elastance (Ea) Septic shock

摘要:
Background: It is still unclear what the minimal infusion volume is to effectively predict fluid responsiveness. This study was designed to explore the minimal infusion volume to effectively predict fluid responsiveness in septic shock patients. Hemodynamic effects of fluid administration on arterial load were observed and added values of effective arterial elastance (Ea) in fluid resuscitation were assessed. Methods: Intensive care unit septic shock patients with indwelling pulmonary artery catheter (PAC) received five sequential intravenous boluses of 100 mL 4% gelatin. Cardiac output (CO) was measured with PAC before and after each bolus. Fluid responsiveness was defined as an increase in CO >10% after 500 mL fluid infusion. Results: Forty-seven patients were included and 35 (74.5%) patients were fluid responders. CO increasing >5.2% after a 200 mL fluid challenge (FC) provided an improved detection of fluid responsiveness, with a specificity of 80.0% and a sensitivity of 91.7%. The area under the ROC curve (AUC) was 0.93 (95% CI: 0.84–1.00, P < 0.001). Fluid administration induced a decrease in Ea from 2.23 (1.46–2.78) mmHg/mL to 1.83 (1.34–2.44) mmHg/mL (P = 0.002), especially for fluid responders in whom arterial pressure did not increase. Notably, the baseline Ea was able to detect the fluid responsiveness with an AUC of 0.74 (95% CI: 0.59– 0.86, P < 0.001), whereas Ea failed to predict the pressure response to FC with an AUC of 0.50 (95% CI: 0.33–0.67, P = 0.086). Conclusion: In septic shock patients, a minimal volume of 200 mL 4% gelatin could reliably detect fluid responders. Fluid administration reduced Ea even when CO increased. The loss of arterial load might be the reason for patients who increased their CO without pressure responsiveness. Moreover, a high level of Ea before FC was able to predict fluid responsiveness rather than to detect the pressure responsiveness.

基金编号: 2020YFC0841300

语种:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 3 区 医学
小类 | 3 区 医学:内科
最新[2023]版:
大类 | 3 区 医学
小类 | 3 区 医学:内科
第一作者:
第一作者机构: [1]北京协和医院
通讯机构: [1]北京协和医院
推荐引用方式(GB/T 7714):

资源点击量:52537 今日访问量:0 总访问量:1562 更新日期:2024-09-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 昆明医科大学第一附属医院 技术支持:重庆聚合科技有限公司 地址:云南省昆明市西昌路295号(650032)